Comparison of the effectiveness of Tokuyama and GC II metal primer on the bond strength of acrylic resins to Ti-6Al-7Nb


Department of Prosthodontics, Faculty of Dental Sciences, King George's Medical University, Lucknow, Uttar Pradesh, India

Date of Web Publication28-Dec-2017

Correspondence Address:
Dr. Balendra Pratap Singh
Flat No. 101, New Teachers Apartment, TG Campus, Khadra, Lucknow, Uttar Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0975-5950.221704

Rights and Permissions
   Abstract 


Statement of Problem: Because of the toxicity of vanadium in Ti-6Al-4V alloy, next generation of titanium alloys is proposed to focus on niobium-containing alloy, but for clinical applications, it is crucial for this alloy to bond with acrylic resins with or without the use of primers. However, literature was lacking about the effect of primers on bonding of autopolymerizing resins to Ti-6Al-7Nb.
Objectives: To evaluate the effect of different metal primers on the shear bond strength of acrylic resin to Ti-6Al-7Nb.
Materials and Methods: A total of 30 dis-shaped wax patterns (10 mm in diameter and 2 mm thickness) were prepared and casted using Ti-6Al-7Nb. After casting, the disk surfaces were finished with abrasive paper under water. Specimens were equally divided into three groups on the basis of the use of primer: metal primer (GC II metal primer) (Group 1), Universal Tokuyama primer (Group 2), no primer (Group 3). Tape of 50 μm thickness was applied on each of the specimens. Then, self-cure acrylic resin was mixed and applied on the center part of the tape, on which Bernouilles tube was placed. The tensile bond strength was measured with a universal testing machine. The data were obtained for all the specimens and analyzed using Statistical Package for Social Sciences version 17.0 at a statistically significance level of <0.05.
Results: Mean tensile force was maximum for Group 2 (28.58 ± 39.40 N) and minimum for control Group 3 (6.24 ± 10.97 N), thereby showing a significant inter-group difference (P < 0.001). On applying post hoc test (Tukey HSD), both the Group 1 and Group 2 showed a statistically significant difference as compared to control Group 3; however, the difference between two experimental groups was not statistically significant (P > 0.05).
Conclusions: Tokuyama primer and GC II metal primer had a significant effect on improving the bond strength between autopolymerizing denture base resin and Ti-6Al-7Nb.

Keywords: Autopolymerizing resin, bond strength, in vitro, primer, titanium alloy


How to cite this article:
Jurel SK, Mishra N, Chand P, Aggarwal H, Singh RD, Singh BP. Comparison of the effectiveness of Tokuyama and GC II metal primer on the bond strength of acrylic resins to Ti-6Al-7Nb. Natl J Maxillofac Surg 2017;8:125-9

How to cite this URL:
Jurel SK, Mishra N, Chand P, Aggarwal H, Singh RD, Singh BP. Comparison of the effectiveness of Tokuyama and GC II metal primer on the bond strength of acrylic resins to Ti-6Al-7Nb. Natl J Maxillofac Surg [serial online] 2017 [cited 2021 Sep 25];8:125-9. Available from: https://www.njms.in/text.asp?2017/8/2/125/221704




   Introduction Top


In removable prosthodontics, sufficient bonding is desirable between the cast metal-based partial or complete denture framework and the denture base resin. Poor chemical bonding of the metal-resin interface may result in significant clinical problems, often introducing adhesive failure and increasing microleakage of oral fluids in the finish lines, which causes an accumulation of oral debris, microorganisms, and stains.[1],[2],[3] Another significant clinical and esthetic problem associated with removable prostheses is the discoloration or staining caused by microleakage. Therefore, optimizing bond strength at the resin-metal interface of a removable partial denture (RPD) is essential for the success of the prosthesis.[4],[5],[6] The differences in the coefficient of thermal expansion between acrylic resins and alloys, and the polymerization shrinkage of acrylic resin, may result in separation of these materials.[7] Resin-to-metal and resin-to-denture tooth bonds are stressed by laboratory procedures during the fabrication of RPDs.[8] The use of titanium and titanium alloys for cast restorations, denture frameworks, and milled prostheses has increased substantially,[9] and several systems have been introduced increasing the bond strength between acrylic resin and RPD casting alloys.[10]

One important improvement in resin bonding techniques has been the introduction of chemical metal-resin bonding systems.[11],[12],[13],[14] Recently, Ohkubo et al.[11] studied the effect of the application of metal conditioners to cast commercially pure (CP) titanium, titanium alloy (Ti-6Al-4V), and Co–Cr alloy. Semlitsch et al.[15] developed a titanium-aluminum alloy with the inert alloying element niobium and found the optimal composition should be Ti-6Al-7Nb. This alloy had outstanding biocompatibility,[16] good mechanical properties and corrosion resistance,[17] reliable casting properties,[12] and improved wear resistance.[13],[14] Yanagida et al.[18] evaluated the effect of metal conditioners and a surface modification system on the bond durability between a light-activated prosthetic composite material and Ti-6Al-7Nb. In their study, the use of the primers was found to enhance bonding. Furthermore, Yanagida et al.[19] evaluated the adhesive performance of metal conditioners used for bonding between autopolymerizing methacrylate resins and a titanium alloy, and reported that the use of one of the three conditioners (Alloy Primer, Cesead II Opaque Primer, and Metal Prime II) in combination with autopolymerizing luting resin consisting of methyl methacrylate and tri-n-butylborane with 4-methacryloyloxyethyl trimellitate anhydride (Super-Bond C and B) is recommended for bonding to the Ti-6Al-7Nb alloy. Several adhesive primers, including Meta Fast (Sun Medical Co. Ltd., Shiga, Japan), containing 4-META monomer, and metal primer (Ivoclar Vivadent AG, Schaan, Liechtenstein), containing 10-methacryloyloxydecyl dihydrogen phosphate, have been developed and are commercially available for resin-bonded prostheses, composite-veneered prostheses, and RPDs.[11] Numerous studies have evaluated the effect of such primers on bonding acrylic resin to Ti-6Al-4V and CP-Ti. However, there is insufficient information about the effect of such primers on bonding of autopolymerizing polymethyl methacrylate (PMMA) resins to Ti-6Al-7Nb.

Hence, the purpose of this study was to compare the effectiveness of Tokuyama primer and GC II primer on tensile bond strength of autopolymerizing PMMA resins to Ti-6Al-7Nb.


   Materials and Methods Top


A total of 30 disk-shaped wax patterns (10 mm in diameter and 2 mm thickness) were prepared and casted using a titanium alloy (Ti-6Al-7Nb), according to the manufacturer's instructions. After casting, the disk surfaces were finished with 600-grit SiC abrasive paper (CarbiMet; Buehler Ltd., Lake Bluff, Ill) under water. To each titanium disc, nuts were fixed with araldite (fixing material), and they were sandblasted with 50 μm particle sized sand at 2.5 bar pressure. After sandblasting, all specimens were steam-cleaned and kept in temperature bath for at 37°C for 24 h. The discs were then removed from temperature bath and tape of 50 μm thickness (bearing central hole) was applied on all the specimens. The specimens were now ready for testing [Figure 1], and equally divided into three groups with ten titanium plates in each group: Group 1 with GC II metal primer, Group 2 with Universal Tokuyama primer, Group 3 with no primer which acts as control group.
Figure 1: Titanium specimens used in the study

Click here to view


The metal primer (GC Corporation Ltd., Tokyo, Japan) was applied with the applicator tip on all the 10 specimens of Group 1. Then, self-cure acrylic resin (UNIFAST III; GC Corp., Tokyo, Japan) was mixed in ratio 1 g powder/0.5 ml liquid and applied on the center part of the tape, on which Bernouilles tube was placed. It was cured at room temperature (23 ± 1°C; humidity 50–60%) and after keeping undisturbed for about 10–15 min, all the specimens with the attached tubes as shown in [Figure 2], was placed in hot air oven at 37°C for 24 h. The universal primer (Tokuyama Dental Corp., Japan) was applied over all the specimens of Group 2 and similar procedure was performed as described for Group 1. Same procedure was performed for Group 3 specimens, but without applying any primer over the disc surface.
Figure 2: Specimens with the attached bernouilles tubes ready for testing

Click here to view


The tensile bond strength was measured with a universal testing machine (TSTM 02500; Elista, Istanbul, Turkey), using a crosshead speed of 0.5 mm/min [Figure 3]. The data were obtained for all the specimens, and it was analyzed using Statistical Package for Social Sciences version 17.0 (SPSS Inc., Chicago, IL). Intergroup comparison was done using analysis of variance followed by Tukey HSD test as the post hoc assessment tool. The confidence level of the study was kept at 95%, hence a P < 0.05 indicated a statistically significant difference.
Figure 3: Universal testing machine used in the study

Click here to view



   Results Top


[Graph 1] summarizes the means and standard deviations of the tensile force of the three groups. The results indicate that the mean tensile force was maximum for Universal Tokuyama primer (28.58 ± 39.40 N) and minimum for control group (6.24 ± 10.97 N), thereby showing a significant intergroup difference (F = 41.966; P < 0.001). On applying post hoc test (Tukey HSD), GC II metal primer and Universal Tokuyama primer showed a statistically significant difference as compared to control group. However, the difference between two GC II metal primer and Universal Tokuyama primer was not significant statistically (P > 0.05).




   Discussion Top


The current study evaluated the effect of GC Primer II and Tokuyama Primer on tensile bond strengths between an autopolymerizing PMMA resin to Ti-6Al-7Nb.

As there are serious concerns on the toxicity of vanadium in Ti-6Al-4V alloy, so the next generation of titanium alloys is proposed to focus on niobium-containing alloy.[20] However, the superior biological [20] and mechanical [21] properties of Ti-6Al-7Nb do not warrant their extensive application in dentistry unless this alloy can be used as an alternative to Ti-6Al-4V or CP-Ti. For practical applications of Ti-6Al-7Nb in prosthodontics, it is crucial for this alloy to bond with acrylic resins with or without the use of primers.

In our study, airborne-particle abrasion was employed to create surface roughness by cleaning the surface of metal oxides and other substances, to increase the mechanical and chemical bond strength between metal and acrylic resin.[9] As the choice of a chemical bonding system for prosthodontic applications depends on factors such as expense, availability, time requirements, and the shelf life of the perishable components.[22] However, a control group (Group 3) was also formed in the present study to check whether the need of primer to bond titanium alloy to acrylic resin could be eliminated. However, it was found that bond strength in this group was approximately four times less than the primer treated groups (Group 1 and 2) as shown in [Graph 1].

Numerous studies have established that application of primers significantly improve the bond strength of the acrylic resin to the cast metals, Ti-6Al-4 V, CP-Ti, composites, and ceramics.[8],[9],[10],[23],[24],[25],[26],[27],[28],[29],[30],[31],[32] However, the comparative evaluations of bond strength between acrylic resin and Ti-6Al-7Nb with the use of Tokuyama primer and GC II metal primer have never been documented. In the present study, the tensile bond strength of Ti-6Al-7Nb to acrylic resins was significantly (P< 0.001) improved by primer application compared to control group [Graph 1]. The mean tensile force was maximum for Group 2 (28.58 ± 39.40 N) and minimum for control Group 3 (6.24 ± 10.97 N), thereby showing a statistically significant intergroup difference (F = 41.966; P < 0.001) Therefore, both Tokuyama primer and GC II metal primer had a statistically significant effect on improving the bond between the autopolymerizing denture base resin and Ti-6Al-7Nb, which can make this alloy feasible for use in removable prosthodontics.

However, as tensile bond strength is not the only factor that may influence the durability of resin-metal bonds, so careful interpretation in the clinical application of these results is suggested, as the design of the present study, did not consider factors existing in the oral environment, such as dynamic fatigue loading and pH changes. The efficacy of the tested systems in providing reliable bond strength needs to be confirmed by long-term clinical studies.


   Conclusions Top


Within the limitation of this in vitro study, it can be concluded that both Tokuyama primer and GC II metal primer had a statistically significant effect on improving the bond strength between autopolymerizing denture base resin and Ti-6Al-7Nb, which can make this alloy feasible for the use in removable prosthodontics as a safe alternative to Ti-6Al-4V.

Acknowledgement

Dr. Sunit Jurel is thankful to Dr Chikahiro Ohkubo, Professor and chairman and Dr. Shigeru Hanatani, Associate Professor from Department of Removable Prosthodontics, Tsurumi University, School of Dental Medicine, Yokohama, Japan.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Lawson JR. Alternative alloys for resin-bonded retainers. J Prosthet Dent 1991;65:97-9.  Back to cited text no. 1
[PUBMED]    
2.
Lino Carracho AJ, Chappell RP, Glaros AG, Purk JH, Eick JD. The effect of storage and thermocycling on the shear bond strength of three dentinal adhesives. Quintessence Int 1991;22:745-52.  Back to cited text no. 2
[PUBMED]    
3.
Yoshida K, Kamada K, Atsuta M. Adhesive primers for bonding cobalt-chromium alloy to resin. J Oral Rehabil 1999;26:475-8.  Back to cited text no. 3
[PUBMED]    
4.
Hansson O. Clinical results with resin-bonded prostheses and an adhesive cement. Quintessence Int 1994;25:125-32.  Back to cited text no. 4
[PUBMED]    
5.
Behr M, Leibrock A, Stich W, Rammelsberg P, Rosentritt M, Handel G. Adhesive-fixed partial dentures in anterior and posterior areas. Results of an on-going prospective study begun in 1985. Clin Oral Investig 1998;2:31-5.  Back to cited text no. 5
[PUBMED]    
6.
Ozcan M, Pfeiffer P, Nergiz I. A brief history and current status of metal-and ceramic surface-conditioning concepts for resin bonding in dentistry. Quintessence Int 1998;29:713-24.  Back to cited text no. 6
[PUBMED]    
7.
Strygler H, Nicholls JI, Townsend JD. Microleakage at the resin-alloy interface of chemically retained composite resins for cast restorations. J Prosthet Dent 1991;65:733-9.  Back to cited text no. 7
[PUBMED]    
8.
Kim JY, Pfeiffer P, Niedermeier W. Effect of laboratory procedures and thermocycling on the shear bond strength of resin-metal bonding systems. J Prosthet Dent 2003;90:184-9.  Back to cited text no. 8
[PUBMED]    
9.
Koizumi H, Furuchi M, Tanoue N, Yanagida H, Yoneyama T, Matsumura H. Bond strength to primed Ti-6Al-7Nb alloy of two acrylic resin adhesives. Dent Mater J 2006;25:286-90.  Back to cited text no. 9
[PUBMED]    
10.
NaBadalung DP, Powers JM. Effectiveness of adhesive systems for a Co-Cr removable partial denture alloy. J Prosthodont 1998;7:17-25.  Back to cited text no. 10
[PUBMED]    
11.
Ohkubo C, Watanabe I, Hosoi T, Okabe T. Shear bond strengths of polymethyl methacrylate to cast titanium and cobalt-chromium frameworks using five metal primers. J Prosthet Dent 2000;83:50-7.  Back to cited text no. 11
[PUBMED]    
12.
Semlitsch MF, Weber H, Streicher RM, Schön R. Joint replacement components made of hot-forged and surface-treated Ti-6Al-7Nb alloy. Biomaterials 1992;13:781-8.  Back to cited text no. 12
    
13.
Lavos-Valereto IC, Wolynec S, Deboni MC, König B Jr.In vitro and in vivo biocompatibility testing of Ti-6Al-7Nb alloy with and without plasma-sprayed hydroxyapatite coating. J Biomed Mater Res 2001;58:727-33.  Back to cited text no. 13
    
14.
Kobayashi E, Wang TJ, Doi H, Yoneyama T, Hamanaka H. Mechanical properties and corrosion resistance of Ti-6Al-7Nb alloy dental castings. J Mater Sci Mater Med 1998;9:567-74.  Back to cited text no. 14
[PUBMED]    
15.
Wang TJ, Kobayashi E, Doi H, Yoneyama T. Castability of Ti-6Al-7Nb alloy for dental casting. J Med Dent Sci 1999;46:13-9.  Back to cited text no. 15
[PUBMED]    
16.
Ohkubo C, Shimura I, Aoki T, Hanatani S, Hosoi T, Okabe T.In vitro wear assessment of titanium alloy teeth. J Prosthodont 2002;11:263-9.  Back to cited text no. 16
[PUBMED]    
17.
Iijima D, Yoneyama T, Doi H, Hamanaka H, Kurosaki N. Wear properties of Ti and Ti-6Al-7Nb castings for dental prostheses. Biomaterials 2003;24:1519-24.  Back to cited text no. 17
[PUBMED]    
18.
Yanagida H, Matsumura H, Atsuta M. Bonding of prosthetic composite material to Ti-6Al-7Nb alloy with eight metal conditioners and a surface modification technique. Am J Dent 2001;14:291-4.  Back to cited text no. 18
[PUBMED]    
19.
Yanagida H, Taira Y, Shimoe S, Atsuta M, Yoneyama T, Matsumura H. Adhesive bonding of titanium-aluminum-niobium alloy with nine surface preparations and three self-curing resins. Eur J Oral Sci 2003;111:170-4.  Back to cited text no. 19
[PUBMED]    
20.
Challa VS, Mali S, Misra RD. Reduced toxicity and superior cellular response of preosteoblasts to Ti-6Al-7Nb alloy and comparison with Ti-6Al-4V. J Biomed Mater Res A 2013;101:2083-9.  Back to cited text no. 20
[PUBMED]    
21.
Bolzoni L, Weissgaerber T, Kieback B, Ruiz-Navas EM, Gordo E. Mechanical behaviour of pressed and sintered CP Ti and Ti-6Al-7Nb alloy obtained from master alloy addition powder. J Mech Behav Biomed Mater 2013;20:149-61.  Back to cited text no. 21
[PUBMED]    
22.
Rothfuss LG, Hokett SD, Hondrum SO, Elrod CW. Resin to metal bond strengths using two commercial systems. J Prosthet Dent 1998;79:270-2.  Back to cited text no. 22
[PUBMED]    
23.
Radhi A, Juszczyk AS, Curtis RV, Sherriff M, Radford DR, Clark RK. Effect of GC METALPRIMER II on bond strength of heat-cured acrylic resin to titanium alloy (Ti-6Al-4V) with two different surface treatments. Eur J Prosthodont Restor Dent 2008;16:132-7.  Back to cited text no. 23
[PUBMED]    
24.
Podder S, Goel P, Kar S, Bhattacharyya J. Investigation into the effect of use of metal primer on adhesion of heat cure acrylic resin to cast titanium: An in vitro study. J Indian Prosthodont Soc 2014;14:262-72.  Back to cited text no. 24
[PUBMED]    
25.
Elzarug YA, Galburt RB, Ali A, Finkelman M, Dam HG. An in vitro comparison of the shear bond strengths of two different gingiva-colored materials bonded to commercially pure titanium and acrylic artificial teeth. J Prosthodont 2014;23:313-9.  Back to cited text no. 25
[PUBMED]    
26.
Almilhatti HJ, Neppelenbroek KH, Vergani CE, Machado AL, Pavarina AC, Giampaolo ET. Adhesive bonding of resin composite to various titanium surfaces using different metal conditioners and a surface modification system. J Appl Oral Sci 2013;21:590-6.  Back to cited text no. 26
[PUBMED]    
27.
Sanohkan S, Urapepon S, Harnirattisai C, Sirisinha C, Sunintaboon P. Shear bond strength between autopolymerizing acrylic resin and Co-Cr alloy using different primers. Dent Mater J 2012;31:765-71.  Back to cited text no. 27
[PUBMED]    
28.
Di Francescantonio M, Oliveira MT, Daroz LG, Henriques GE, Giannini M. Adhesive bonding of resin cements to cast titanium with adhesive primers. Braz Dent J 2012;23:218-22.  Back to cited text no. 28
[PUBMED]    
29.
Koizuka M, Komine F, Blatz MB, Fushiki R, Taguchi K, Matsumura H. The effect of different surface treatments on the bond strength of a gingiva-colored indirect composite veneering material to three implant framework materials. Clin Oral Implants Res 2013;24:977-84.  Back to cited text no. 29
[PUBMED]    
30.
Bulbul M, Kesim B. The effect of primers on shear bond strength of acrylic resins to different types of metals. J Prosthet Dent 2010;103:303-8.  Back to cited text no. 30
[PUBMED]    
31.
Matsuda Y, Yanagida H, Ide T, Matsumura H, Tanoue N. Bond strength of poly(methyl methacrylate) denture base material to cast titanium and cobalt-chromium alloy. J Adhes Dent 2010;12:223-9.  Back to cited text no. 31
[PUBMED]    
32.
Lee G, Engelmeier RL, Gonzalez M, Powers JM, Perezous LF, O'Keefe KL. Force needed to separate acrylic resin from primed and unprimed frameworks of different designs. J Prosthodont 2010;19:14-9.  Back to cited text no. 32
    


    Figures

  [Figure 1], [Figure 2], [Figure 3]


This article has been cited by
1 Adhesion between Biocomposites and Different Metallic Structures Additive Manufactured
Stanca Cuc,Alexandru Burde,Cosmin Cosma,Dan Leordean,Mircea Rusu,Nicolae Balc,Doina Prodan,Marioara Moldovan,Razvan Ene
Coatings. 2021; 11(4): 483
[Pubmed] | [DOI]



 

Top
   
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
    Materials and Me...
   Results
   Discussion
   Conclusions
    References
    Article Figures

 Article Access Statistics
    Viewed965    
    Printed44    
    Emailed0    
    PDF Downloaded180    
    Comments [Add]    
    Cited by others 1    

Recommend this journal