Home | About us | Editorial board | Ahead of print | Current issue | Archives | Search | Submit article | Instructions | Subscribe | Advertise | Contact us |  Login 
National Journal of Maxillofacial Surgery
 
Print this page Email this page Small font sizeDefault font sizeIncrease font size
Users Online: 403
 
ORIGINAL ARTICLE
Year : 2020  |  Volume : 11  |  Issue : 1  |  Page : 40-45

Effect of 4% nebulized lignocaine versus 2% nebulized lignocaine for awake fibroscopic nasotracheal intubation in maxillofacial surgeries


1 Department of Anaesthesiology, KGMU, Lucknow, Uttar Pradesh, India
2 Department of Anaesthesiology, AIIMS, Jodhpur, Rajasthan, India

Correspondence Address:
Dr. Nikhil Kothari
Department of Anaesthesiology, AIIMS, Jodhpur, Rajasthan
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/njms.NJMS_71_17

Rights and Permissions

Introduction: Securing a difficult airway during maxillofacial surgeries is a great challenge for anesthetists, and the flexible fiber-optic bronchoscope is the gold standard while managing such cases. While passing the flexible bronchoscope by the nasal route, the success rate is higher as compared with oral approach as the nasopharynx is in line with the larynx and prevents acute angulation in the oropharynx. Materials and Methods: A randomized control trial was planned in 73 patients out of whom sixty patients gave consent for the procedure. The patients we randomly divided into two groups (n = 30) with application of 4% nebulized lignocaine in one group and the use of 2% nebulized lignocaine in the other group, and the patient's comfort was noted using five-point Puchner scale. Results: The mean value of patient comfort Puchner scale of Group A was 1.30 ± 0.08 and of Group B was 2.23 ± 0.12. The mean value of Puchner scale of Group B was significantly higher (41.8%) as compared to Group A (t = 6.208; df = 51; P < 0.0001). The secondary outcome measures were optimal intubating conditions and hemodynamic changes during awake fiber-optic nasotracheal intubation. The procedural time of two groups when compared showed that the mean procedural time of Group A was shorter (29.67 ± 5.40 min) than the time consumed in Group B (34.93 ± 5.52 min). Conclusion: Four percent nebulized lidocaine provided adequate airway anesthesia and optimal intubating conditions along with stable hemodynamics for awake fiber-optic intubation as compared to 2% nebulized lidocaine.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed171    
    Printed9    
    Emailed0    
    PDF Downloaded39    
    Comments [Add]    

Recommend this journal