Home | About us | Editorial board | Ahead of print | Current issue | Archives | Search | Submit article | Instructions | Subscribe | Advertise | Contact us |  Login 
National Journal of Maxillofacial Surgery
 
Print this page Email this page Small font sizeDefault font sizeIncrease font size
Users Online: 212
 
ORIGINAL ARTICLE
Year : 2011  |  Volume : 2  |  Issue : 1  |  Page : 54-62

Evaluation of implants placed immediately or delayed into extraction sites


Department of Oral and Maxillofacial Surgery, Faculty of Dental Sciences, C. S. M. Medical University, Lucknow, India

Correspondence Address:
U S Pal
Department of Oral and Maxillofacial Surgery, CSM Medical University, Lucknow - 226003, Uttar Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0975-5950.85855

Rights and Permissions

Aims and objectives: To compare the success rate of implant placed immediately in extraction socket vs implant placed delayed in extraction socket. Materials and Methods: The study comprised of 8 patients (6 male and 2 female, aged from 14 to 58 year) for evaluation of implant placement immediately (i.e. Group - A) or delayed (i.e. Group - B) into extraction site, in which at 12 sites implants were placed. Results: The inclusion criteria for implantation was tooth/teeth with one or two degree mobility, root stumps, tooth with failure root canal treatment and extraction sockets. HI-TEC TRX-OP (Life Care) with abutment, non-submerged, tapered at apical 5 mm, sand-blasted & acid etched surfaced implants were used. These are one stage single implants made of commercially pure titanium. The length of implants used was 10 mm and 13 mm and diameter was 3.70 mm and 4.50 mm. The vertical bone dimension was determined by palpation and radiograph (intra-oral periapical, orthopantomograph and dentascan in some patients). Gingival condition, bone condition was examined clinically and radiographically. Discussion: Post-operative evaluation was done under clinical parameters (i.e. Pain (VAS), Swelling, Stability (By Glickman method), Gingival status, Probing depth (By Williams Periodontal probe), Patient's compliance / satisfaction, Complications (If any) and Radiological parameters was (Intra-oral periapical radiograph, orthopantomograph, Dentascan). Conclusion: Overall conclusion drawn from this study was that both the groups are showing similar results but Group-A is slightly better than Group-B


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2937    
    Printed151    
    Emailed1    
    PDF Downloaded711    
    Comments [Add]    
    Cited by others 1    

Recommend this journal